Hydraulics move gear, flaps, brakes and flight controls because a little fluid at high pressure gives a lot of force (force = pressure × area), and the fluid can be piped anywhere.
The parts
Reservoir: holds fluid, often pressurized to keep the pump fed.
Pump: hand, engine-driven or electric; constant or variable displacement.
Relief valve: opens if pressure goes too high, protecting the system.
Pressure regulator: unloads a constant-displacement pump when pressure is reached.
Accumulator: a sphere or cylinder with nitrogen on one side of a piston or bladder; stores pressure, dampens surges and gives emergency power. Its nitrogen preload is checked with the system's fluid pressure bled off to zero.
Check valve: flow one way only.
Selector valve: sends fluid to one side of an actuator or the other.
Actuator: a cylinder (single or double acting) or a motor that does the work.
Filters: keep the fluid clean; many have a bypass that opens if they clog.
Fluids
There are different fluids, and their seals are made for one type only: mixing them or using the wrong seals ruins the system.
Mineral based (MIL-PRF-5606): dyed red, flammable, used in light aircraft; seals of neoprene or Buna-N.
Synthetic hydrocarbon (MIL-PRF-87257 and similar): also red, more fire resistant, used in military aircraft.
Phosphate ester (Skydrol and similar): purple or other light colors, fire resistant, used in airliners; seals of butyl or ethylene-propylene. It irritates eyes and skin and strips paint, so wear protection.
Pneumatics
Some aircraft use compressed air or nitrogen bottles for emergency gear extension and brakes. Lower pressure air from the engines (bleed air) or pumps runs de-ice boots and gyro instruments (vacuum systems).
1Reservoir
2Pump
3Relief valvelimits pressure
4Selector valve
5Actuatordoes the work
Return
1Actuator
2Selector valve
3Filter
4Reservoir
A simple hydraulic system
Practice
Which hydraulic component protects the system if pressure rises too high?
More info
Quick reference
Relief valve
Opens when pressure is too high.
Accumulator
Stores pressure on a nitrogen preload; checked with fluid pressure at zero.
Check valve
One-way flow.
Selector valve
Routes fluid to one side of an actuator.
MIL-PRF-5606
Red mineral fluid; Buna-N or neoprene seals.
Phosphate ester
Purple, fire resistant; butyl or EPR seals; harsh on skin and paint.